GUYMASTER Release Notes for version 2.0.7 as of February 1, 2010 ---------------------------------------- We are releasing an update for GUYMASTER to corect the following: 1) The monopole routine calculation of the drag factor, Cd, and height factor, Ce. In the calculation of the Cd factor in metric units, the pole diameter, Dp, was treated as if it were in Imperial units. The limiton the value of Ce, S37-01 Clause 4.5.1, was not imposed. It is now 0.9 <= Ce <= 2.0 2) In the monopole graph report of the Shell Stresses were being reported in KN, but should be in MPa. 3) The drag factor for a pole with more than 18-sides will now be taken as being the same as for a round pole.